sales@zmscable.com
  • NYBY Cable

    NYBY Cable

    NYBY cable are applied for power distribution in city networks, industrial plants and on the places where mechanical damages are expected. May be laid in the ground, cable ducts and in open air.
  • ZMS Cable company mainly provides complete supply services for distributors and suppliers all over the world.

    Consulting services, purchasing services, transportation services, and after-sales services are included.


    Application

    NYBY power cable 0,6/1 kV with Cu conductors, PVC insulated and sheathed.

    Distribution of power cable for static application, mostly in-ground, but also in water, within facilities, in cable canals, and in concrete.

    Used in electric power plants, transformer stations, industrial plants, metropolitan networks, and other electric plants.

    Applied in conditions requiring protection against heavier mechanical damages, but where cables are not exposed to heavier tensile strain.

    Standard

    HRN HD 603 S1

    IEC 60502-1

    DIN VDE 0276 part 603

    cables with 6 and more conductors:

    HRN HD 627 S1

    DIN VDE 027

    Construction

    Conductor: Cu, class 1 or 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295

    Class 1: solid, round (RE)

    Class 2: multi-wire stranded, round (RM) or sector (SM), multi-wire exceeding 50 mm² are compacted

    Insulation: PVC compound, concentrically stranded cores, color-marked acc. to HRN HD 308 S2 / VDE 0293-308, with or without a protective yellow-green conductor

    Filler: spouted elastomer or elastomer compound or wrapped thermoplastic tapes

    Armor: double galvanized steel tapes

    Sheath: PVC compound

    Sheath Colour: black

    Types

    Low Voltage Armoured Cable Nyby

    CONTROL CABLES NYBY

    NYBY ARMOURED POWER CABLE

    Good Quality 0.6/1KV 4C underground Armoured power cable NYBY

    Technical Data

    Temperature Range

    during installation: -5 °C up to +50 °C

    fixed installed: -30 °C up to +70 °C

    at short circuit of max. 5 s: up to 160 °C

    Voltage

    Nominal voltage: Uο/U = 0.6/1 kV NYBY Cable

    Test voltage: 4 kV

    Maximal tensile strength: 50 N/mm²

    Behavior in fire: IEC 60332-1

    Minimal inner bending radius

    single-core: 15D

    multi-core: 12D

    Special version upon request

    Cross-sectional area customized

    Aluminum conductor required

    Advantages

    Excellent electric and mechanical characteristics

    Best Resistance to chemical corrosion and heat-aging, environment stress, and flame-retardant

    Simple in structure, Convenient to use

    Reduce costs